# Foundation Pier: Building Code Definition

> How the IBC 2009 define foundation pier, where the wording differs, and which chapters depend on the term.

- Canonical: https://harth.build/resources/glossary/foundation-pier/
- Last updated: 2026-09-07
- Data source: Definitions quoted from the 2009 International Codes as transcribed in this site's building-codes collection, with the source chapter linked for each quotation. Usage counts are computed over the chapters hosted here, one copy per code. The [ICC code library](https://codes.iccsafe.org/codes) publishes the current model text and the [ICC adoption maps](https://www.iccsafe.org/advocacy/code-adoption-maps/) show which edition a jurisdiction has adopted; those sources control.

## Key facts

| Fact | Value |
| --- | --- |
| Defined in | IBC 2009 (2009 editions transcribed in this corpus) |
| Primary source | IBC 2009 Masonry (model text, not a jurisdiction's adopted text) |
| Chapters using the term | 3 (counted across the codes hosted here) |
| Wording identical across codes | Single code (compare before citing one code's wording under another) |

## Direct answer

Foundation pier is a defined term in the International Building Code (IBC) 2009, in Masonry. The code's own words are: “An isolated vertical foundation member whose horizontal dimension measured at right angles to its thickness does not exceed three times its thickness and whose height is equal to or less than four times its thickness.” No other I-Code in this corpus defines it, so the IBC 2009 definition is the one to work from. The term is used in 3 chapters of this corpus, most often in Definitions (IBC 2009), Masonry (IBC 2009), Soils and Foundations (IBC 2009). These pages transcribe the 2009 model text; verify the definition against the edition and amendments your authority having jurisdiction has adopted. Record the jurisdiction, the adopted edition, the application date and any local amendment that rewrites the definition before you use it on a live project, because a term redefined by amendment changes every requirement that depends on it.

*Content and cited inputs reviewed by [Scott Barrington](https://nz.linkedin.com/in/barrington), Harth founder and architectural technology specialist · Published 2026-09-07 · Updated 2026-09-07.*

## What does this term mean?

**Foundation Pier** — IBC 2009, Masonry:

> An isolated vertical foundation member whose horizontal dimension measured at right angles to its thickness does not exceed three times its thickness and whose height is equal to or less than four times its thickness.

![Labeled code-term definition diagram: Foundation Pier: Building Code Definition](https://efwwel0vyt9vy5so.public.blob.vercel-storage.com/images/glossary/foundation-pier/diagram-1344.webp)

*How the IBC 2009 define foundation pier, where the wording differs, and which chapters depend on the term.*

## What must be verified before using this guidance?

**Foundation Pier** is defined once in this corpus, in the [Masonry](https://harth.build/resources/building-codes/us-states/maryland/ibc-2009/masonry.md) chapter of the International Building Code (IBC) 2009:

> An isolated vertical foundation member whose horizontal dimension measured at right angles to its thickness does not exceed three times its thickness and whose height is equal to or less than four times its thickness.

## Where foundation pier is used in the code

The term appears in 3 chapters of the 2009 I-Codes hosted here. The chapters that lean on it hardest are the ones to read next.

| Chapter | Code | Mentions |
| --- | --- | --- |
| [Definitions](https://harth.build/resources/building-codes/us-states/maryland/ibc-2009/definitions.md) | IBC 2009 | 1 |
| [Masonry](https://harth.build/resources/building-codes/us-states/maryland/ibc-2009/masonry.md) | IBC 2009 | 1 |
| [Soils and Foundations](https://harth.build/resources/building-codes/us-states/maryland/ibc-2009/soils-and-foundations.md) | IBC 2009 | 1 |

## The terms foundation pier is built out of

The definition above leans on 1 other defined term. Each carries its own code definition, and a local amendment to any of them changes what foundation pier covers:

- **[Isolated](https://harth.build/resources/glossary/isolated.md)** — IRC 2009: (As applied to location.) Not readily accessible to persons unless special means for access are used.

## Foundation Pier: what to open, and in what order

Every row is a document this term depends on. The [ICC code library](https://codes.iccsafe.org/codes) and the [ICC adoption maps](https://www.iccsafe.org/advocacy/code-adoption-maps/) cover the middle rows.

| Check | Where | Confirmed |
| --- | --- | --- |
| Read the definition in the adopted IBC | Masonry | |
| Re-check the requirement that uses it | Definitions (IBC 2009) | |
| Re-check the requirement that uses it | Masonry (IBC 2009) | |
| Re-check the requirement that uses it | Soils and Foundations (IBC 2009) | |
| Confirm the dependent definition | Isolated | |
| Local amendment to any of the above | Jurisdiction's amendment list | |

**A research aid, not a code determination.** The authority having jurisdiction decides which edition and which amendments apply.

## Where can you explore related guidance?

- [Explore all glossary guidance](https://harth.build/resources/glossary.md)
- [Isolated: Building Code Definition](https://harth.build/resources/glossary/isolated.md)
- [Chimney: Building Code Definition](https://harth.build/resources/glossary/chimney.md)
- [Tile: Building Code Definition](https://harth.build/resources/glossary/tile.md)
- [Fireplace: Building Code Definition](https://harth.build/resources/glossary/fireplace.md)

## Sources and method

Definitions quoted from the 2009 International Codes as transcribed in this site's building-codes collection, with the source chapter linked for each quotation. Usage counts are computed over the chapters hosted here, one copy per code. The [ICC code library](https://codes.iccsafe.org/codes) publishes the current model text and the [ICC adoption maps](https://www.iccsafe.org/advocacy/code-adoption-maps/) show which edition a jurisdiction has adopted; those sources control.

### Source links

- [codes.iccsafe.org](https://codes.iccsafe.org/codes)

- [iccsafe.org](https://www.iccsafe.org/advocacy/code-adoption-maps/)

## Frequently asked questions

### What is the code definition of foundation pier?

The International Building Code (IBC) 2009 defines it in Masonry as: “An isolated vertical foundation member whose horizontal dimension measured at right angles to its thickness does not exceed three times its thickness and whose height is equal to or less than four times its thickness.” The 2009 model text is reproduced here; the definition that binds your project is the one in the edition your jurisdiction has adopted, as amended locally.

### Which parts of the code depend on foundation pier?

In this corpus the term is used across 3 chapters, led by Definitions in the IBC 2009. Those are the sections whose scope moves if the definition is amended locally, so read them together with Chapter 2 rather than on their own.

### What is the definition of a foundation pier?

In the 2009 I-Codes hosted here it is a defined term rather than a description. The IBC 2009 states, in Masonry: “An isolated vertical foundation member whose horizontal dimension measured at right angles to its thickness does not exceed three times its thickness and whose height is equal to or less than four times its thickness.” It is defined in IBC 2009. Because it is a defined term, whatever the adopted edition says it means is what every section using it means — so check Chapter 2 of that edition and any local amendment before relying on this wording.

### What is the meaning of "pier" in building construction?

Building is a separate defined term. The IBC 2009 defines it as: “Any structure used or intended for supporting or sheltering any use or occupancy.” That is not the same as foundation pier, which the IBC 2009 defines as “An isolated vertical foundation member whose horizontal dimension measured at right angles to its thickness does not exceed three times its thickness and whose height is equal to or less than four times its thickness.” — read both before applying either, and confirm the wording in the edition your jurisdiction has adopted.

---

- Continue in Harth (open this topic in the Harth agent): https://app.harth.build/agent?context=%2Fresources%2Fglossary%2Ffoundation-pier%2F
- View this page in a browser: https://harth.build/resources/glossary/foundation-pier/
- All resources for agents: https://harth.build/llms.txt