Climate & Energy Design Data
Climate Design Data: Santol, Philippines
How to research climate design data for a specific site in Santol — the controlling authority, source documents, and checks to run before you rely on a number.
Last updated August 31, 2026 · Location data from the [GeoNames PH dump](https://download.geonames.org/export/dump/PH.zip) (CC BY 4.0, snapshot 2026-08-31, GeoNames ID 1687687). Regulatory starting point: [Department of Public Works and Highways and the local Office of the Building Official](https://www.dpwh.gov.ph/dpwh/references/laws_codes_orders/PD1096). Figures are illustrative — verify against the current locally adopted edition for the site. Climate screening data from the [NASA POWER Climatology API documentation](https://power.larc.nasa.gov/docs/services/api/temporal/climatology/) and [exact point response](https://power.larc.nasa.gov/api/temporal/climatology/point?parameters=T2M%2CT2M_MAX%2CT2M_MIN%2CRH2M%2CPRECTOTCORR%2CWS10M&community=SB&longitude=120.5675&latitude=15.16222&format=JSON), retrieved 2026-08-31; source period: 20-year Meteorological and Solar Monthly & Annual Climatologies (January 2001 - December 2020). NASA POWER values are gridded screening statistics, not code design conditions or guaranteed local observations.
Direct answer
NASA POWER's 2001–2020 climatology at the Santol reference point reports an annual mean 2 m temperature of 26.5 °C and relative humidity of 81.2%. The highest monthly maximum is 40.3 °C in May, while the lowest monthly minimum is 15.7 °C in January; these are screening statistics, not code design temperatures. The point response uses LST and the 20-year Meteorological and Solar Monthly & Annual Climatologies (January 2001 - December 2020); its annual corrected precipitation is 7.51 mm/day and annual 10 m wind speed is 3.38 m/s. For climate design data, use the 40.3 °C and 15.7 °C monthly extrema to screen seasonal exposure, then obtain the adopted percentile design conditions. NASA POWER is gridded climatology: verify elevation, microclimate, urban exposure, station or weather-file suitability, current code edition and the authority's required source before design use.
Prepared by Harth · Harth transformed the cited NASA POWER climatology into this screening table; project design conditions and local applicability remain unreviewed · Published 2026-08-26 · Updated 2026-08-31.
What must be verified for Santol?
Santol is represented here at approximately 15.1622, 120.5675 for discovery and workflow planning. A project address, parcel, elevation, exposure, authority, and submission date must replace that city-centre reference before design use.
How should climate design data be established?
- Fix the surveyed site and local time basis.
- Select an authoritative weather source or a named solar-position algorithm.
- Record period, percentile or scenario and units.
- Test sensitivity to elevation, exposure, urban form and horizon.
- Save the source file, retrieval date and checker in the model record.
| Input | Project-specific evidence | QA question |
|---|---|---|
| Site | surveyed coordinates, elevation and horizon | Does the point represent the building? |
| Weather/solar method | named dataset, algorithm, period and time basis | Are station, time zone and units explicit? |
| Design scenario | current and future scenario agreed by the team | Is an average being mistaken for an extreme? |
| Compliance | adopted local document and edition | Was applicability confirmed with the authority? |
What are the limits of this worksheet?
This climate-design-workflow page is a project-starting worksheet, not a design value or approval. The controlling authority and qualified professionals for the Santol site remain authoritative.
Which related searches does this primary location record cover?
This primary route consolidates the location evidence needed for Climate Design Data, Weather File Guide, Overheating Weather Data, Building Climate Checklist. A narrower route should be released only when it adds a materially different official source, calculation, process, threshold or worked example.
Santol NASA POWER monthly climate screening table
| Month | Mean °C | Monthly max °C | Monthly min °C | RH % | Precipitation mm/day | Wind at 10 m m/s |
|---|---|---|---|---|---|---|
| January | 24.44 | 33.93 | 15.67 | 79.79 | 0.89 | 4.15 |
| February | 25.55 | 36.76 | 16.30 | 74.01 | 1.05 | 4.08 |
| March | 27.43 | 38.75 | 17.78 | 68.47 | 1.02 | 3.78 |
| April | 29.36 | 40.00 | 20.59 | 64.69 | 1.61 | 3.21 |
| May | 28.93 | 40.28 | 22.65 | 73.54 | 6.37 | 2.69 |
| June | 27.33 | 38.19 | 21.86 | 84.30 | 13.17 | 2.84 |
| July | 26.47 | 32.65 | 21.84 | 88.37 | 16.84 | 3.11 |
| August | 26.25 | 32.19 | 21.26 | 89.98 | 19.61 | 3.60 |
| September | 26.28 | 32.83 | 22.34 | 89.07 | 14.44 | 2.79 |
| October | 25.99 | 31.64 | 18.61 | 87.83 | 7.61 | 2.83 |
| November | 25.42 | 33.20 | 16.55 | 88.13 | 4.11 | 3.46 |
| December | 24.72 | 33.21 | 17.00 | 85.84 | 2.94 | 4.07 |
Santol ranked monthly climate fingerprint
- Santol mean temperature, highest to lowest: April 29.36 °C, May 28.93 °C, March 27.43 °C, June 27.33 °C, July 26.47 °C, September 26.28 °C, August 26.25 °C, October 25.99 °C, February 25.55 °C, November 25.42 °C, December 24.72 °C, January 24.44 °C.
- Santol monthly maximum, highest to lowest: May 40.28 °C, April 40.00 °C, March 38.75 °C, June 38.19 °C, February 36.76 °C, January 33.93 °C, December 33.21 °C, November 33.20 °C, September 32.83 °C, July 32.65 °C, August 32.19 °C, October 31.64 °C.
- Santol monthly minimum, highest to lowest: May 22.65 °C, September 22.34 °C, June 21.86 °C, July 21.84 °C, August 21.26 °C, April 20.59 °C, October 18.61 °C, March 17.78 °C, December 17.00 °C, November 16.55 °C, February 16.30 °C, January 15.67 °C.
- Santol relative humidity, highest to lowest: August 89.98 %, September 89.07 %, July 88.37 %, November 88.13 %, October 87.83 %, December 85.84 %, June 84.30 %, January 79.79 %, February 74.01 %, May 73.54 %, March 68.47 %, April 64.69 %.
- Santol corrected precipitation, highest to lowest: August 19.61 mm/day, July 16.84 mm/day, September 14.44 mm/day, June 13.17 mm/day, October 7.61 mm/day, May 6.37 mm/day, November 4.11 mm/day, December 2.94 mm/day, April 1.61 mm/day, February 1.05 mm/day, March 1.02 mm/day, January 0.89 mm/day.
- Santol 10 m wind speed, highest to lowest: January 4.15 m/s, February 4.08 m/s, December 4.07 m/s, March 3.78 m/s, August 3.60 m/s, November 3.46 m/s, April 3.21 m/s, July 3.11 m/s, June 2.84 m/s, October 2.83 m/s, September 2.79 m/s, May 2.69 m/s.
Santol month-to-month screening ledger
- Santol January: mean 24.44 °C, change from December -0.28 °C; max–min span 18.26 °C; humidity 79.79%, change -6.05 points; precipitation 0.89 mm/day; wind 4.15 m/s.
- Santol February: mean 25.55 °C, change from January +1.11 °C; max–min span 20.46 °C; humidity 74.01%, change -5.78 points; precipitation 1.05 mm/day; wind 4.08 m/s.
- Santol March: mean 27.43 °C, change from February +1.88 °C; max–min span 20.97 °C; humidity 68.47%, change -5.54 points; precipitation 1.02 mm/day; wind 3.78 m/s.
- Santol April: mean 29.36 °C, change from March +1.93 °C; max–min span 19.41 °C; humidity 64.69%, change -3.78 points; precipitation 1.61 mm/day; wind 3.21 m/s.
- Santol May: mean 28.93 °C, change from April -0.43 °C; max–min span 17.63 °C; humidity 73.54%, change +8.85 points; precipitation 6.37 mm/day; wind 2.69 m/s.
- Santol June: mean 27.33 °C, change from May -1.60 °C; max–min span 16.33 °C; humidity 84.30%, change +10.76 points; precipitation 13.17 mm/day; wind 2.84 m/s.
- Santol July: mean 26.47 °C, change from June -0.86 °C; max–min span 10.81 °C; humidity 88.37%, change +4.07 points; precipitation 16.84 mm/day; wind 3.11 m/s.
- Santol August: mean 26.25 °C, change from July -0.22 °C; max–min span 10.93 °C; humidity 89.98%, change +1.61 points; precipitation 19.61 mm/day; wind 3.60 m/s.
- Santol September: mean 26.28 °C, change from August +0.03 °C; max–min span 10.49 °C; humidity 89.07%, change -0.91 points; precipitation 14.44 mm/day; wind 2.79 m/s.
- Santol October: mean 25.99 °C, change from September -0.29 °C; max–min span 13.03 °C; humidity 87.83%, change -1.24 points; precipitation 7.61 mm/day; wind 2.83 m/s.
- Santol November: mean 25.42 °C, change from October -0.57 °C; max–min span 16.65 °C; humidity 88.13%, change +0.30 points; precipitation 4.11 mm/day; wind 3.46 m/s.
- Santol December: mean 24.72 °C, change from November -0.70 °C; max–min span 16.21 °C; humidity 85.84%, change -2.29 points; precipitation 2.94 mm/day; wind 4.07 m/s.
Harth retrieved this point climatology from NASA POWER API v2.9.7 for location record 1687687. The ranked fingerprint and transition ledger preserve Santol's monthly order and successive changes for source comparison. This is a reproducible screening dataset, not an hourly weather file, forecast, code design condition or substitute for local professional review.
Where can you explore related guidance?
- Explore all climate data guidance
- Climate Design Data: Angeles City, Philippines
- Climate Design Data: Tarlac City, Philippines
- Climate Design Data: Cabanatuan City, Philippines
- Climate Design Data: San Jose del Monte, Philippines
- All climate & energy design data guidance for Philippines
- Sun Path: Santol, Philippines
Sources and method
Location data from the GeoNames PH dump (CC BY 4.0, snapshot 2026-08-31, GeoNames ID 1687687). Regulatory starting point: Department of Public Works and Highways and the local Office of the Building Official. Figures are illustrative — verify against the current locally adopted edition for the site. Climate screening data from the NASA POWER Climatology API documentation and exact point response, retrieved 2026-08-31; source period: 20-year Meteorological and Solar Monthly & Annual Climatologies (January 2001 - December 2020). NASA POWER values are gridded screening statistics, not code design conditions or guaranteed local observations.
Source links
Frequently asked questions
What does NASA POWER climatology show for Santol?
For the Santol reference point, the 2001–2020 NASA POWER climatology reports 26.5 °C annual mean temperature, 81.2% relative humidity and 7.51 mm/day corrected precipitation. The monthly maximum peaks at 40.3 °C in May.
Can the Santol climatology replace project design temperatures or an hourly weather file?
No. The Santol response is gridded monthly climatology; its lowest monthly minimum of 15.7 °C in January is not a code percentile or observed site extreme. Verify elevation, local exposure, the required weather file or design-condition source and the current adopted code.
Related pages
- Climate Design Data: San Jose del Monte, Philippines
San Jose del Monte, Philippines climate design data (NASA POWER 2001–2020): annual mean 25.3 °C, monthly max 38.4 °C (May), min 16.0 °C (January), RH 86%.
- Climate Design Data: San Pablo, Philippines
San Pablo, Philippines climate design data (NASA POWER 2001–2020): annual mean 25.9 °C, monthly max 37.9 °C (August), min 16.0 °C (January), RH 85%.
- Climate Design Data: Sandakan, Malaysia
Sandakan, Malaysia climate design data (NASA POWER 2001–2020): annual mean 27.2 °C, monthly max 32.0 °C (May), min 23.1 °C (February), RH 85%; monthly table.
- Climate Design Data: Saskatoon, Canada
Saskatoon, Canada climate design data (NASA POWER 2001–2020): annual mean 3.6 °C, monthly max 37.7 °C (July), min -44.9 °C (January), RH 73%; monthly table.
- Climate Design Data: Selayang Baru Utara, Malaysia
Selayang Baru Utara, Malaysia climate design data (NASA POWER 2001–2020): annual mean 24.6 °C, monthly max 32.3 °C (March), min 15.9 °C (February), RH 88%.
- Climate Design Data: Seremban, Malaysia
Seremban, Malaysia climate design data (NASA POWER 2001–2020): annual mean 27.2 °C, monthly max 35.0 °C (April), min 20.7 °C (February), RH 82%; monthly table.