Building Code Glossary
Dry Floodproofing: Building Code Definition
How the IBC 2009 define dry floodproofing, where the wording differs, and which chapters depend on the term.
On this page
Last updated September 7, 2026 · Definitions quoted from the 2009 International Codes as transcribed in this site's building-codes collection, with the source chapter linked for each quotation. Usage counts are computed over the chapters hosted here, one copy per code. The [ICC code library](https://codes.iccsafe.org/codes) publishes the current model text and the [ICC adoption maps](https://www.iccsafe.org/advocacy/code-adoption-maps/) show which edition a jurisdiction has adopted; those sources control.
Direct answer
Dry floodproofing is a defined term in the International Building Code (IBC) 2009, in Structural Design. The code's own words are: “A combination of design modifications that results in a building or structure, including the attendant utility and sanitary facilities, being water tight with walls substantially impermeable to the passage of water and with structural components having the capacity to resist loads as identified in ASCE 7.” No other I-Code in this corpus defines it, so the IBC 2009 definition is the one to work from. The term is used in 2 chapters of this corpus, most often in Structural Design (IBC 2009), Definitions (IBC 2009). These pages transcribe the 2009 model text; verify the definition against the edition and amendments your authority having jurisdiction has adopted.
Content and cited inputs reviewed by Scott Barrington, Harth founder and architectural technology specialist · Published 2026-09-07 · Updated 2026-09-07.
What does this term mean?
Dry Floodproofing — IBC 2009, Structural Design:
A combination of design modifications that results in a building or structure, including the attendant utility and sanitary facilities, being water tight with walls substantially impermeable to the passage of water and with structural components having the capacity to resist loads as identified in ASCE 7.

What must be verified before using this guidance?
Dry Floodproofing is defined once in this corpus, in the Structural Design chapter of the International Building Code (IBC) 2009:
A combination of design modifications that results in a building or structure, including the attendant utility and sanitary facilities, being water tight with walls substantially impermeable to the passage of water and with structural components having the capacity to resist loads as identified in ASCE 7.
Where dry floodproofing is used in the code
The term appears in 2 chapters of the 2009 I-Codes hosted here. The chapters that lean on it hardest are the ones to read next.
| Chapter | Code | Mentions |
|---|---|---|
| Structural Design | IBC 2009 | 4 |
| Definitions | IBC 2009 | 1 |
The term in use
How the code actually writes about dry floodproofing, quoted from the 2009 text hosted here:
For dry floodproofed nonresidential buildings, construction documents shall include a statement that the dry floodproofing is designed in accordance with ASCE 24.
The terms dry floodproofing is built out of
The definition above leans on 4 other defined terms. Each carries its own code definition, and a local amendment to any of them changes what dry floodproofing covers:
- Identified — IRC 2009: (As applied to equipment.) Recognizable as suitable for the specific purpose, function, use, environment, application, etc., where described in a particular code requirement.
- Structure — IPC 2009: That which is built or constructed or a portion thereof.
- Building — IBC 2009: Any structure used or intended for supporting or sheltering any use or occupancy.
- Loads — IBC 2009: Forces or other actions that result from the weight of building materials, occupants and their possessions, environmental effects, differential movement and restrained dimensional changes.
Dry Floodproofing: what to open, and in what order
Every row is a document this term depends on. The ICC code library and the ICC adoption maps cover the middle rows.
| Check | Where | Confirmed |
|---|---|---|
| Read the definition in the adopted IBC | Structural Design | |
| Re-check the requirement that uses it | Structural Design (IBC 2009) | |
| Re-check the requirement that uses it | Definitions (IBC 2009) | |
| Confirm the dependent definition | Identified | |
| Confirm the dependent definition | Structure | |
| Confirm the dependent definition | Building | |
| Local amendment to any of the above | Jurisdiction's amendment list |
A research aid, not a code determination. The authority having jurisdiction decides which edition and which amendments apply.
Where can you explore related guidance?
- Explore all glossary guidance
- Identified: Building Code Definition
- Structure: Building Code Definition
- Building: Building Code Definition
- Loads: Building Code Definition
Sources and method
Definitions quoted from the 2009 International Codes as transcribed in this site's building-codes collection, with the source chapter linked for each quotation. Usage counts are computed over the chapters hosted here, one copy per code. The ICC code library publishes the current model text and the ICC adoption maps show which edition a jurisdiction has adopted; those sources control.
Source links
Frequently asked questions
What is the code definition of dry floodproofing?
The International Building Code (IBC) 2009 defines it in Structural Design as: “A combination of design modifications that results in a building or structure, including the attendant utility and sanitary facilities, being water tight with walls substantially impermeable to the passage of water and with structural components having the capacity to resist loads as identified in ASCE 7.” The 2009 model text is reproduced here; the definition that binds your project is the one in the edition your jurisdiction has adopted, as amended locally.
Which parts of the code depend on dry floodproofing?
In this corpus the term is used across 2 chapters, led by Structural Design in the IBC 2009. Those are the sections whose scope moves if the definition is amended locally, so read them together with Chapter 2 rather than on their own.
What is the difference between wet and dry floodproofing?
In the 2009 I-Codes hosted here it is a defined term rather than a description. The IBC 2009 states, in Structural Design: “A combination of design modifications that results in a building or structure, including the attendant utility and sanitary facilities, being water tight with walls substantially impermeable to the passage of water and with structural components having the capacity to resist loads as identified in ASCE 7.” It is defined in IBC 2009. Because it is a defined term, whatever the adopted edition says it means is what every section using it means — so check Chapter 2 of that edition and any local amendment before relying on this wording.
Related pages
- Dry Cleaning Room: Building Code Definition
Dry Cleaning Room — IFC 2009 definition: An occupiable space within a building used for performing dry cleaning operations, the installation ofsolvent-handling equipment …
- Dry Cleaning System: Building Code Definition
Dry Cleaning System — IFC 2009 definition: Machinery or equipment in which textiles are immersed or agitated in solvent or in which dry …
- Dry Cleaning: Building Code Definition
Dry Cleaning — IFC 2009 definition: The process of removing dirt, grease, paints and other stains from such items as wearing apparel …
- Duct Furnace: Building Code Definition
Duct Furnace — IRC 2009 definition: A warm-air furnace normally installed in an air-distribution duct to supply warm air for heating.
- Duct System: Building Code Definition
Duct System — IRC 2009 definition: A continuous passageway for the transmission of air which, in addition to ducts, includes duct fittings …
- Duct: Building Code Definition
Duct — IMC 2009 definition: A tube or conduit utilized for conveying air.