Updated 2026-09-07

Building Code Glossary

Ground-fault Circuit-interrupter: Building Code Definition

How the IRC 2009 define ground-fault circuit-interrupter, where the wording differs, and which chapters depend on the term.

On this page

Last updated September 7, 2026 · Definitions quoted from the 2009 International Codes as transcribed in this site's building-codes collection, with the source chapter linked for each quotation. Usage counts are computed over the chapters hosted here, one copy per code. The [ICC code library](https://codes.iccsafe.org/codes) publishes the current model text and the [ICC adoption maps](https://www.iccsafe.org/advocacy/code-adoption-maps/) show which edition a jurisdiction has adopted; those sources control.

Direct answer

Ground-fault circuit-interrupter is a defined term in the International Residential Code (IRC) 2009, in Electrical Definitions. The code's own words are: “A device intended for the protection of personnel that functions to de-energize a circuit or portion thereof within an established period of time when a current to ground exceeds the value for a Class A device.” No other I-Code in this corpus defines it, so the IRC 2009 definition is the one to work from. The term is used in 4 chapters of this corpus, most often in Swimming Pools (IRC 2009), Power and Lighting Distribution (IRC 2009), Appliance Installation (IRC 2009). These pages transcribe the 2009 model text; verify the definition against the edition and amendments your authority having jurisdiction has adopted.

Content and cited inputs reviewed by Scott Barrington, Harth founder and architectural technology specialist · Published 2026-09-07 · Updated 2026-09-07.

What does this term mean?

Ground-fault Circuit-interrupter — IRC 2009, Electrical Definitions:

A device intended for the protection of personnel that functions to de-energize a circuit or portion thereof within an established period of time when a current to ground exceeds the value for a Class A device.

Labeled code-term definition diagram: Ground-fault Circuit-interrupter: Building Code Definition
How the IRC 2009 define ground-fault circuit-interrupter, where the wording differs, and which chapters depend on the term.

What must be verified before using this guidance?

Ground-fault Circuit-interrupter is defined once in this corpus, in the Electrical Definitions chapter of the International Residential Code (IRC) 2009:

A device intended for the protection of personnel that functions to de-energize a circuit or portion thereof within an established period of time when a current to ground exceeds the value for a Class A device.

Where ground-fault circuit-interrupter is used in the code

The term appears in 4 chapters of the 2009 I-Codes hosted here. The chapters that lean on it hardest are the ones to read next.

The term in use

How the code actually writes about ground-fault circuit-interrupter, quoted from the 2009 text hosted here:

All 15- and 20-ampere, single phase, 125-volt receptacles located within 20 feet (6096 mm) of the inside walls of pools and outdoor spas and hot tubs shall be protected by a ground-fault circuit-interrupter.

IRC 2009 §E4203.1.3

All 125-volt, single-phase, 15- and 20-ampere receptacles installed in bathrooms shall have ground-fault circuit-interrupter protection for personnel.

IRC 2009 §E3902.1

Outdoor receptacles that are not readily accessible and are supplied from a dedicated branch circuit for electric snow-melting or deicing equipment shall be permitted to be installed without ground-fault circuit-interrupter protection for personnel.

IRC 2009 §E4101.7

The terms ground-fault circuit-interrupter is built out of

The definition above leans on 1 other defined term. Each carries its own code definition, and a local amendment to any of them changes what ground-fault circuit-interrupter covers:

  • Device — IRC 2009: Aunit of an electrical system that carries or controls electrical energy as it principal function.

Ground-fault Circuit-interrupter: what to open, and in what order

Every row is a document this term depends on. The ICC code library and the ICC adoption maps cover the middle rows.

CheckWhereConfirmed
Read the definition in the adopted IRCElectrical Definitions
Re-check the requirement that uses itSwimming Pools (IRC 2009)
Re-check the requirement that uses itPower and Lighting Distribution (IRC 2009)
Re-check the requirement that uses itAppliance Installation (IRC 2009)
Re-check the requirement that uses itElectrical Definitions (IRC 2009)
Confirm the dependent definitionDevice
Local amendment to any of the aboveJurisdiction's amendment list

A research aid, not a code determination. The authority having jurisdiction decides which edition and which amendments apply.

Sources and method

Definitions quoted from the 2009 International Codes as transcribed in this site's building-codes collection, with the source chapter linked for each quotation. Usage counts are computed over the chapters hosted here, one copy per code. The ICC code library publishes the current model text and the ICC adoption maps show which edition a jurisdiction has adopted; those sources control.

Frequently asked questions

What is the code definition of ground-fault circuit-interrupter?

The International Residential Code (IRC) 2009 defines it in Electrical Definitions as: “A device intended for the protection of personnel that functions to de-energize a circuit or portion thereof within an established period of time when a current to ground exceeds the value for a Class A device.” The 2009 model text is reproduced here; the definition that binds your project is the one in the edition your jurisdiction has adopted, as amended locally.

Which parts of the code depend on ground-fault circuit-interrupter?

In this corpus the term is used across 4 chapters, led by Swimming Pools in the IRC 2009. Those are the sections whose scope moves if the definition is amended locally, so read them together with Chapter 2 rather than on their own.