Last updated September 7, 2026 · Definitions quoted from the 2009 International Codes as transcribed in this site's building-codes collection, with the source chapter linked for each quotation. Usage counts are computed over the chapters hosted here, one copy per code. The [ICC code library](https://codes.iccsafe.org/codes) publishes the current model text and the [ICC adoption maps](https://www.iccsafe.org/advocacy/code-adoption-maps/) show which edition a jurisdiction has adopted; those sources control.

Direct answer

Essentially toxic transfer fluids is a defined term in the International Residential Code (IRC) 2009, in Definitions. The code's own words are: “Soil, water or gray water and fluids having a Gosselin rating of 2 or more including ethylene glycol, hydrocarbon oils, ammonia refrigerants and hydrazine.” The IPC 2009 defines the same term with different wording, so the controlling text depends on which code governs the question in front of you — the comparison below sets the versions side by side. The term is used in 2 chapters of this corpus, most often in Definitions (IPC 2009), Definitions (IRC 2009). These pages transcribe the 2009 model text; verify the definition against the edition and amendments your authority having jurisdiction has adopted.

Content and cited inputs reviewed by Scott Barrington, Harth founder and architectural technology specialist · Published 2026-09-07 · Updated 2026-09-07.

What does this term mean?

Essentially Toxic Transfer Fluids — IRC 2009, Definitions:

Soil, water or gray water and fluids having a Gosselin rating of 2 or more including ethylene glycol, hydrocarbon oils, ammonia refrigerants and hydrazine.

Labeled code-term definition diagram: Essentially Toxic Transfer Fluids: Building Code Definition
How the IRC 2009, IPC 2009 define essentially toxic transfer fluids, where the wording differs, and which chapters depend on the term.

What must be verified before using this guidance?

Two of the I-Codes in this corpus define Essentially Toxic Transfer Fluids, and the wording is not identical — read the version that governs your question.

CodeWhere it is definedDefinition
IRC 2009DefinitionsSoil, water or gray water and fluids having a Gosselin rating of 2 or more including ethylene glycol, hydrocarbon oils, ammonia refrigerants and hydrazine.
IPC 2009DefinitionsSoil, waste or gray water and fluids having a Gosselin rating of 2 or more including ethylene glycol, hydrocarbon oils, ammonia refrigerants and hydrazine.

Where essentially toxic transfer fluids is used in the code

The term appears in 2 chapters of the 2009 I-Codes hosted here. The chapters that lean on it hardest are the ones to read next.

ChapterCodeMentions
DefinitionsIPC 20091
DefinitionsIRC 20091

The terms essentially toxic transfer fluids is built out of

The definition above leans on 1 other defined term. Each carries its own code definition, and a local amendment to any of them changes what essentially toxic transfer fluids covers:

  • Waste — IRC 2009: Liquid-borne waste that is free of fecal matter.

Essentially Toxic Transfer Fluids: what to open, and in what order

Every row is a document this term depends on. The ICC code library and the ICC adoption maps cover the middle rows.

CheckWhereConfirmed
Read the definition in the adopted IRCDefinitions
Read the definition in the adopted IPCDefinitions
Re-check the requirement that uses itDefinitions (IPC 2009)
Re-check the requirement that uses itDefinitions (IRC 2009)
Confirm the dependent definitionWaste
Local amendment to any of the aboveJurisdiction's amendment list

A research aid, not a code determination. The authority having jurisdiction decides which edition and which amendments apply.

Sources and method

Definitions quoted from the 2009 International Codes as transcribed in this site's building-codes collection, with the source chapter linked for each quotation. Usage counts are computed over the chapters hosted here, one copy per code. The ICC code library publishes the current model text and the ICC adoption maps show which edition a jurisdiction has adopted; those sources control.

Frequently asked questions

What is the code definition of essentially toxic transfer fluids?

The International Residential Code (IRC) 2009 defines it in Definitions as: “Soil, water or gray water and fluids having a Gosselin rating of 2 or more including ethylene glycol, hydrocarbon oils, ammonia refrigerants and hydrazine.” The 2009 model text is reproduced here; the definition that binds your project is the one in the edition your jurisdiction has adopted, as amended locally.

Which parts of the code depend on essentially toxic transfer fluids?

In this corpus the term is used across 2 chapters, led by Definitions in the IPC 2009. Those are the sections whose scope moves if the definition is amended locally, so read them together with Chapter 2 rather than on their own.