Building Code Glossary
Limit Control: Building Code Definition
How the IMC 2009 define limit control, where the wording differs, and which chapters depend on the term.
On this page
Last updated September 7, 2026 · Definitions quoted from the 2009 International Codes as transcribed in this site's building-codes collection, with the source chapter linked for each quotation. Usage counts are computed over the chapters hosted here, one copy per code. The [ICC code library](https://codes.iccsafe.org/codes) publishes the current model text and the [ICC adoption maps](https://www.iccsafe.org/advocacy/code-adoption-maps/) show which edition a jurisdiction has adopted; those sources control.
Direct answer
Limit control is a defined term in the International Mechanical Code (IMC) 2009, in Definitions. The code's own words are: “A device responsive to changes in pressure, temperature or level for turning on, shutting off or throttling the gas supply to an appliance.” No other I-Code in this corpus defines it, so the IMC 2009 definition is the one to work from. The term is used in 3 chapters of this corpus, most often in Hazardous Materials-general Provisions (IFC 2009), Cryogenic Fluids (IFC 2009), Definitions (IMC 2009). These pages transcribe the 2009 model text; verify the definition against the edition and amendments your authority having jurisdiction has adopted. Record the jurisdiction, the adopted edition, the application date and any local amendment that rewrites the definition before you use it on a live project, because a term redefined by amendment changes every requirement that depends on it.
Content and cited inputs reviewed by Scott Barrington, Harth founder and architectural technology specialist · Published 2026-09-07 · Updated 2026-09-07.
What does this term mean?
Limit Control — IMC 2009, Definitions:
A device responsive to changes in pressure, temperature or level for turning on, shutting off or throttling the gas supply to an appliance.

What must be verified before using this guidance?
Limit Control is defined once in this corpus, in the Definitions chapter of the International Mechanical Code (IMC) 2009:
A device responsive to changes in pressure, temperature or level for turning on, shutting off or throttling the gas supply to an appliance.
Where limit control is used in the code
The term appears in 3 chapters of the 2009 I-Codes hosted here. The chapters that lean on it hardest are the ones to read next.
| Chapter | Code | Mentions |
|---|---|---|
| Hazardous Materials-general Provisions | IFC 2009 | 16 |
| Cryogenic Fluids | IFC 2009 | 6 |
| Definitions | IMC 2009 | 1 |
The term in use
How the code actually writes about limit control, quoted from the 2009 text hosted here:
Atmospheric tanks having a capacity greater than 500 gallons (1893 L) and which contain hazardous material liquids shall be equipped with a liquid-level limit control or other approved means to prevent overfilling of the tank.
The terms limit control is built out of
The definition above leans on 2 other defined terms. Each carries its own code definition, and a local amendment to any of them changes what limit control covers:
- Appliance — IRC 2009: Utilization equipment, normally built in standardized sizes or types, that is installed or connected as a unit to perform one or more functions such as clothes washing, air conditioning, food mixing, deep frying, etc.
- Device — IRC 2009: Aunit of an electrical system that carries or controls electrical energy as it principal function.
Limit Control: what to open, and in what order
Every row is a document this term depends on. The ICC code library and the ICC adoption maps cover the middle rows.
| Check | Where | Confirmed |
|---|---|---|
| Read the definition in the adopted IMC | Definitions | |
| Re-check the requirement that uses it | Hazardous Materials-general Provisions (IFC 2009) | |
| Re-check the requirement that uses it | Cryogenic Fluids (IFC 2009) | |
| Re-check the requirement that uses it | Definitions (IMC 2009) | |
| Confirm the dependent definition | Appliance | |
| Confirm the dependent definition | Device | |
| Local amendment to any of the above | Jurisdiction's amendment list |
A research aid, not a code determination. The authority having jurisdiction decides which edition and which amendments apply.
Where can you explore related guidance?
Sources and method
Definitions quoted from the 2009 International Codes as transcribed in this site's building-codes collection, with the source chapter linked for each quotation. Usage counts are computed over the chapters hosted here, one copy per code. The ICC code library publishes the current model text and the ICC adoption maps show which edition a jurisdiction has adopted; those sources control.
Source links
Frequently asked questions
What is the code definition of limit control?
The International Mechanical Code (IMC) 2009 defines it in Definitions as: “A device responsive to changes in pressure, temperature or level for turning on, shutting off or throttling the gas supply to an appliance.” The 2009 model text is reproduced here; the definition that binds your project is the one in the edition your jurisdiction has adopted, as amended locally.
Which parts of the code depend on limit control?
In this corpus the term is used across 3 chapters, led by Hazardous Materials-general Provisions in the IFC 2009. Those are the sections whose scope moves if the definition is amended locally, so read them together with Chapter 2 rather than on their own.
What is the definition of "limiting distance" in the BC building code?
Building is a separate defined term. The IBC 2009 defines it as: “Any structure used or intended for supporting or sheltering any use or occupancy.” That is not the same as limit control, which the IMC 2009 defines as “A device responsive to changes in pressure, temperature or level for turning on, shutting off or throttling the gas supply to an appliance.” — read both before applying either, and confirm the wording in the edition your jurisdiction has adopted.
What is the definition of a control area?
Control Area is a separate defined term. The IBC 2009 defines it as: “Spaces within a building where quantities of hazardous materials not exceeding the maximum allowable quantities per control area are stored, dispensed, used or handled. See also the definition of "Outdoor control area" in the International Fire Code.” That is not the same as limit control, which the IMC 2009 defines as “A device responsive to changes in pressure, temperature or level for turning on, shutting off or throttling the gas supply to an appliance.” — read both before applying either, and confirm the wording in the edition your jurisdiction has adopted.
What is a limit control?
In the 2009 I-Codes hosted here it is a defined term rather than a description. The IMC 2009 states, in Definitions: “A device responsive to changes in pressure, temperature or level for turning on, shutting off or throttling the gas supply to an appliance.” It is defined in IMC 2009. Because it is a defined term, whatever the adopted edition says it means is what every section using it means — so check Chapter 2 of that edition and any local amendment before relying on this wording.
Related pages
- Light-duty Cooking Appliance: Building Code Definition
Light-duty Cooking Appliance — IMC 2009 definition: Light-duty cooking appliances include gas and electric ovens (including standard, bake, roasting, revolving, retherm, co…
- Light-frame Construction: Building Code Definition
Light-frame Construction — IBC 2009 definition: A type of construction whose vertical and horizontal structural elements are primarily formed by a system …
- Lighting Outlet: Building Code Definition
Lighting Outlet — IRC 2009 definition: An outlet intended for the direct connection of a lampholder or luminaire.
- Limited Spraying Space: Building Code Definition
Limited Spraying Space — IFC 2009 definition: An area in which operations for touch-up or spot painting of a surface area of 9 …
- Liquefied Natural Gas (LNG): Building Code Definition
Liquefied Natural Gas (LNG) — IFC 2009 definition: A fluid in the liquid state composed predominantly of methane and which may contain minor quantities …
- Liquid Oxygen Ambulatory Container: Building Code Definition
Liquid Oxygen Ambulatory Container — IFC 2009 definition: A container used for liquid oxygen not exceeding 0.396 gallons (1.5 liters) specifically designed for use …
The AI-powered workspace for architects.