Limited Spraying Space: Building Code Definition
How the IFC 2009 define limited spraying space, where the wording differs, and which chapters depend on the term.
On this page
Last updated September 7, 2026 · Definitions quoted from the 2009 International Codes as transcribed in this site's building-codes collection, with the source chapter linked for each quotation. Usage counts are computed over the chapters hosted here, one copy per code. The [ICC code library](https://codes.iccsafe.org/codes) publishes the current model text and the [ICC adoption maps](https://www.iccsafe.org/advocacy/code-adoption-maps/) show which edition a jurisdiction has adopted; those sources control.
Direct answer
Limited spraying space is a defined term in the International Fire Code (IFC) 2009, in Flammable Finishes. The code's own words are: “An area in which operations for touch-up or spot painting of a surface area of 9 square feet (0.84 m2) or less are conducted.” No other I-Code in this corpus defines it, so the IFC 2009 definition is the one to work from. The term is used in 3 chapters of this corpus, most often in Flammable Finishes (IFC 2009), Exhaust Systems (IMC 2009), Definitions (IFC 2009). These pages transcribe the 2009 model text; verify the definition against the edition and amendments your authority having jurisdiction has adopted. Record the jurisdiction, the adopted edition, the application date and any local amendment that rewrites the definition before you use it on a live project, because a term redefined by amendment changes every requirement that depends on it.
Content and cited inputs reviewed by Scott Barrington, Harth founder and architectural technology specialist · Published 2026-09-07 · Updated 2026-09-07.
What does this term mean?
Limited Spraying Space — IFC 2009, Flammable Finishes:
An area in which operations for touch-up or spot painting of a surface area of 9 square feet (0.84 m2) or less are conducted.

What must be verified before using this guidance?
Limited Spraying Space is defined once in this corpus, in the Flammable Finishes chapter of the International Fire Code (IFC) 2009:
An area in which operations for touch-up or spot painting of a surface area of 9 square feet (0.84 m2) or less are conducted.
Where limited spraying space is used in the code
The term appears in 3 chapters of the 2009 I-Codes hosted here. The chapters that lean on it hardest are the ones to read next.
| Chapter | Code | Mentions |
|---|---|---|
| Flammable Finishes | IFC 2009 | 7 |
| Exhaust Systems | IMC 2009 | 4 |
| Definitions | IFC 2009 | 1 |
The term in use
How the code actually writes about limited spraying space, quoted from the 2009 text hosted here:
Electrical wiring within 10 feet (3048 mm) of the floor and 20 feet (6096 mm) horizontally of the limited spraying space shall be designed for Class I, Division 2 locations in accordance with NFPA 70.
Limited Spraying Space: what to open, and in what order
Every row is a document this term depends on. The ICC code library and the ICC adoption maps cover the middle rows.
| Check | Where | Confirmed |
|---|---|---|
| Read the definition in the adopted IFC | Flammable Finishes | |
| Re-check the requirement that uses it | Flammable Finishes (IFC 2009) | |
| Re-check the requirement that uses it | Exhaust Systems (IMC 2009) | |
| Re-check the requirement that uses it | Definitions (IFC 2009) | |
| Local amendment to any of the above | Jurisdiction's amendment list |
A research aid, not a code determination. The authority having jurisdiction decides which edition and which amendments apply.
Where can you explore related guidance?
- Explore all glossary guidance
- Spray Booth: Building Code Definition
- Dip Tank: Building Code Definition
- Spray Room: Building Code Definition
- Flammable Finishes: Building Code Definition
Sources and method
Definitions quoted from the 2009 International Codes as transcribed in this site's building-codes collection, with the source chapter linked for each quotation. Usage counts are computed over the chapters hosted here, one copy per code. The ICC code library publishes the current model text and the ICC adoption maps show which edition a jurisdiction has adopted; those sources control.
Source links
Frequently asked questions
What is the code definition of limited spraying space?
The International Fire Code (IFC) 2009 defines it in Flammable Finishes as: “An area in which operations for touch-up or spot painting of a surface area of 9 square feet (0.84 m2) or less are conducted.” The 2009 model text is reproduced here; the definition that binds your project is the one in the edition your jurisdiction has adopted, as amended locally.
Which parts of the code depend on limited spraying space?
In this corpus the term is used across 3 chapters, led by Flammable Finishes in the IFC 2009. Those are the sections whose scope moves if the definition is amended locally, so read them together with Chapter 2 rather than on their own.
Related pages
- Light-frame Construction: Building Code Definition
Light-frame Construction — IBC 2009 definition: A type of construction whose vertical and horizontal structural elements are primarily formed by a system …
- Lighting Outlet: Building Code Definition
Lighting Outlet — IRC 2009 definition: An outlet intended for the direct connection of a lampholder or luminaire.
- Limit Control: Building Code Definition
Limit Control — IMC 2009 definition: A device responsive to changes in pressure, temperature or level for turning on, shutting off or …
- Liquefied Natural Gas (LNG): Building Code Definition
Liquefied Natural Gas (LNG) — IFC 2009 definition: A fluid in the liquid state composed predominantly of methane and which may contain minor quantities …
- Liquid Oxygen Ambulatory Container: Building Code Definition
Liquid Oxygen Ambulatory Container — IFC 2009 definition: A container used for liquid oxygen not exceeding 0.396 gallons (1.5 liters) specifically designed for use …
- Liquid Oxygen Home Care Container: Building Code Definition
Liquid Oxygen Home Care Container — IFC 2009 definition: A container used for liquid oxygen not exceeding 15.8 gallons (60 liters) specifically designed for use …
The AI-powered workspace for architects.