Membrane-penetration Firestop: Building Code Definition

How the IBC 2009 define membrane-penetration firestop, where the wording differs, and which chapters depend on the term.

On this page

Last updated September 7, 2026 · Definitions quoted from the 2009 International Codes as transcribed in this site's building-codes collection, with the source chapter linked for each quotation. Usage counts are computed over the chapters hosted here, one copy per code. The [ICC code library](https://codes.iccsafe.org/codes) publishes the current model text and the [ICC adoption maps](https://www.iccsafe.org/advocacy/code-adoption-maps/) show which edition a jurisdiction has adopted; those sources control.

Direct answer

Membrane-penetration firestop is a defined term in the International Building Code (IBC) 2009, in Fire and Smoke Protection Features. The code's own words are: “A material, device or construction installed to resist for a prescribed time period the passage of flame and heat through openings in a protective membrane in order to accommodate cables, cable trays, conduit, tubing, pipes or similar items.” No other I-Code in this corpus defines it, so the IBC 2009 definition is the one to work from. The term is used in 2 chapters of this corpus, most often in Fire and Smoke Protection Features (IBC 2009), Definitions (IBC 2009). These pages transcribe the 2009 model text; verify the definition against the edition and amendments your authority having jurisdiction has adopted.

Content and cited inputs reviewed by Scott Barrington, Harth founder and architectural technology specialist · Published 2026-09-07 · Updated 2026-09-07.

What does this term mean?

Membrane-penetration Firestop — IBC 2009, Fire and Smoke Protection Features:

A material, device or construction installed to resist for a prescribed time period the passage of flame and heat through openings in a protective membrane in order to accommodate cables, cable trays, conduit, tubing, pipes or similar items.

Labeled code-term definition diagram: Membrane-penetration Firestop: Building Code Definition
How the IBC 2009 define membrane-penetration firestop, where the wording differs, and which chapters depend on the term.

What must be verified before using this guidance?

Membrane-penetration Firestop is defined once in this corpus, in the Fire and Smoke Protection Features chapter of the International Building Code (IBC) 2009:

A material, device or construction installed to resist for a prescribed time period the passage of flame and heat through openings in a protective membrane in order to accommodate cables, cable trays, conduit, tubing, pipes or similar items.

Where membrane-penetration firestop is used in the code

The term appears in 2 chapters of the 2009 I-Codes hosted here. The chapters that lean on it hardest are the ones to read next.

ChapterCodeMentions
Fire and Smoke Protection FeaturesIBC 20092
DefinitionsIBC 20091

The terms membrane-penetration firestop is built out of

The definition above leans on 1 other defined term. Each carries its own code definition, and a local amendment to any of them changes what membrane-penetration firestop covers:

  • Device — IRC 2009: Aunit of an electrical system that carries or controls electrical energy as it principal function.

Membrane-penetration Firestop: what to open, and in what order

Every row is a document this term depends on. The ICC code library and the ICC adoption maps cover the middle rows.

CheckWhereConfirmed
Read the definition in the adopted IBCFire and Smoke Protection Features
Re-check the requirement that uses itFire and Smoke Protection Features (IBC 2009)
Re-check the requirement that uses itDefinitions (IBC 2009)
Confirm the dependent definitionDevice
Local amendment to any of the aboveJurisdiction's amendment list

A research aid, not a code determination. The authority having jurisdiction decides which edition and which amendments apply.

Sources and method

Definitions quoted from the 2009 International Codes as transcribed in this site's building-codes collection, with the source chapter linked for each quotation. Usage counts are computed over the chapters hosted here, one copy per code. The ICC code library publishes the current model text and the ICC adoption maps show which edition a jurisdiction has adopted; those sources control.

Frequently asked questions

What is the code definition of membrane-penetration firestop?

The International Building Code (IBC) 2009 defines it in Fire and Smoke Protection Features as: “A material, device or construction installed to resist for a prescribed time period the passage of flame and heat through openings in a protective membrane in order to accommodate cables, cable trays, conduit, tubing, pipes or similar items.” The 2009 model text is reproduced here; the definition that binds your project is the one in the edition your jurisdiction has adopted, as amended locally.

Which parts of the code depend on membrane-penetration firestop?

In this corpus the term is used across 2 chapters, led by Fire and Smoke Protection Features in the IBC 2009. Those are the sections whose scope moves if the definition is amended locally, so read them together with Chapter 2 rather than on their own.