Building Code Glossary
Constantly Attended Location: Building Code Definition
How the IBC 2009, IFC 2009 define constantly attended location, where the wording differs, and which chapters depend on the term.
On this page
Last updated September 7, 2026 · Definitions quoted from the 2009 International Codes as transcribed in this site's building-codes collection, with the source chapter linked for each quotation. Usage counts are computed over the chapters hosted here, one copy per code. The [ICC code library](https://codes.iccsafe.org/codes) publishes the current model text and the [ICC adoption maps](https://www.iccsafe.org/advocacy/code-adoption-maps/) show which edition a jurisdiction has adopted; those sources control.
Direct answer
Constantly attended location is a defined term in the International Building Code (IBC) 2009, in Fire Protection Systems. The code's own words are: “A designated location at a facility staffed by trained personnel on a continuous basis where alarm or supervisory signals are monitored and facilities are provided for notification of the fire department or other emergency services.” The IFC 2009 defines the same term with different wording, so the controlling text depends on which code governs the question in front of you — the comparison below sets the versions side by side. The term is used in 9 chapters of this corpus, most often in Fire Protection Systems (IFC 2009), Fire Protection Systems (IBC 2009), Duct Systems (IMC 2009). These pages transcribe the 2009 model text; verify the definition against the edition and amendments your authority having jurisdiction has adopted.
Content and cited inputs reviewed by Scott Barrington, Harth founder and architectural technology specialist · Published 2026-09-07 · Updated 2026-09-07.
What does this term mean?
Constantly Attended Location — IBC 2009, Fire Protection Systems:
A designated location at a facility staffed by trained personnel on a continuous basis where alarm or supervisory signals are monitored and facilities are provided for notification of the fire department or other emergency services.

What must be verified before using this guidance?
Two of the I-Codes in this corpus define Constantly Attended Location, and the wording is not identical — read the version that governs your question.
| Code | Where it is defined | Definition |
|---|---|---|
| IBC 2009 | Fire Protection Systems | A designated location at a facility staffed by trained personnel on a continuous basis where alarm or supervisory signals are monitored and facilities are provided for notification of the fire department or other emergency services. |
| IFC 2009 | Fire Protection Systems | A designated location at a facility staffed by trained personnel on a continu0us basis where alarm or supervisory signals are monitored and facilities are provided for notification of the fire department or other emergency services. |
Where constantly attended location is used in the code
The term appears in 9 chapters of the 2009 I-Codes hosted here. The chapters that lean on it hardest are the ones to read next.
| Chapter | Code | Mentions |
|---|---|---|
| Fire Protection Systems | IFC 2009 | 30 |
| Fire Protection Systems | IBC 2009 | 23 |
| Duct Systems | IMC 2009 | 5 |
| Flammable and Combustible Liquids | IFC 2009 | 3 |
| Means of Egress | IFC 2009 | 3 |
| Compressed Gases | IFC 2009 | 2 |
| Definitions | IBC 2009 | 1 |
| Means of Egress | IBC 2009 | 1 |
| Definitions | IFC 2009 | 1 |
The term in use
How the code actually writes about constantly attended location, quoted from the 2009 text hosted here:
Alarm, supervisory and trouble signals shall be distinctly different and shall be automatically transmitted to an approved supervising station or, when approved by the fire code official, shall sound an audible signal at a constantly attended location.
The actuation of a duct smoke detector shall activate a visible and audible supervisory signal at a constantly attended location.
Activation of either vapor or liquid detection systems shall cause a signal to be sounded at an approved, constantly attended location within the facility serving the tanks or at an approved location.
The terms constantly attended location is built out of
The definition above leans on 1 other defined term. Each carries its own code definition, and a local amendment to any of them changes what constantly attended location covers:
- Facility — IBC 2009: All or any portion of buildings, structures, site improvements, elements and pedestrian or vehicular routes located on a site.
Constantly Attended Location: what to open, and in what order
Every row is a document this term depends on. The ICC code library and the ICC adoption maps cover the middle rows.
| Check | Where | Confirmed |
|---|---|---|
| Read the definition in the adopted IBC | Fire Protection Systems | |
| Read the definition in the adopted IFC | Fire Protection Systems | |
| Re-check the requirement that uses it | Fire Protection Systems (IFC 2009) | |
| Re-check the requirement that uses it | Fire Protection Systems (IBC 2009) | |
| Re-check the requirement that uses it | Duct Systems (IMC 2009) | |
| Re-check the requirement that uses it | Flammable and Combustible Liquids (IFC 2009) | |
| Confirm the dependent definition | Facility | |
| Local amendment to any of the above | Jurisdiction's amendment list |
A research aid, not a code determination. The authority having jurisdiction decides which edition and which amendments apply.
Where can you explore related guidance?
- Explore all glossary guidance
- Facility: Building Code Definition
- Automatic: Building Code Definition
- Zone: Building Code Definition
- Automatic Sprinkler System: Building Code Definition
Sources and method
Definitions quoted from the 2009 International Codes as transcribed in this site's building-codes collection, with the source chapter linked for each quotation. Usage counts are computed over the chapters hosted here, one copy per code. The ICC code library publishes the current model text and the ICC adoption maps show which edition a jurisdiction has adopted; those sources control.
Source links
Frequently asked questions
What is the code definition of constantly attended location?
The International Building Code (IBC) 2009 defines it in Fire Protection Systems as: “A designated location at a facility staffed by trained personnel on a continuous basis where alarm or supervisory signals are monitored and facilities are provided for notification of the fire department or other emergency services.” The 2009 model text is reproduced here; the definition that binds your project is the one in the edition your jurisdiction has adopted, as amended locally.
Which parts of the code depend on constantly attended location?
In this corpus the term is used across 9 chapters, led by Fire Protection Systems in the IFC 2009. Those are the sections whose scope moves if the definition is amended locally, so read them together with Chapter 2 rather than on their own.
What does a continuous fire alarm mean?
Fire Alarm is a separate defined term. The IFC 2009 defines it as: “The giving, signaling or transmission to any public fire station, or company or to any officer or employee thereof, whether by telephone, spoken word or otherwise, of information to the effect that there is a fire at or near the place” That is not the same as constantly attended location, which the IBC 2009 defines as “A designated location at a facility staffed by trained personnel on a continuous basis where alarm or supervisory signals are monitored and facilities are provided for notification of the fire department or other emergency services.” — read both before applying either, and confirm the wording in the edition your jurisdiction has adopted.
Related pages
- Conduit Body: Building Code Definition
Conduit Body — IRC 2009 definition: A separate portion of a conduit or tubing system that provides access through a removable cover(s) …
- Congregate Living Facilities: Building Code Definition
Congregate Living Facilities — IBC 2009 definition: A building or part thereof that contains sleeping units where residents share bathroom and/or kitchen facilities.
- Connector: Building Code Definition
Connector — IBC 2009 definition: A mechanical device for securing two or more pieces, parts or members together, including anchors, wall …
- Construction Documents: Building Code Definition
Construction Documents — IBC 2009 definition: Written, graphic and pictorial documents prepared or assembled for describing the design, location and physical characteristics …
- Container: Building Code Definition
Container — IFC 2009 definition: A vessel of 60 gallons (227 L) or less in capacity used for transporting or storing …
- Containment System: Building Code Definition
Containment System — IFC 2009 definition: A gas-tight recovery system comprised of equipment or devices which can be placed over a leak …
The AI-powered workspace for architects.