Updated 2026-09-07

Building Code Glossary

Electrostatic Fluidized Bed: Building Code Definition

How the IFC 2009 define electrostatic fluidized bed, where the wording differs, and which chapters depend on the term.

On this page

Last updated September 7, 2026 · Definitions quoted from the 2009 International Codes as transcribed in this site's building-codes collection, with the source chapter linked for each quotation. Usage counts are computed over the chapters hosted here, one copy per code. The [ICC code library](https://codes.iccsafe.org/codes) publishes the current model text and the [ICC adoption maps](https://www.iccsafe.org/advocacy/code-adoption-maps/) show which edition a jurisdiction has adopted; those sources control.

Direct answer

Electrostatic fluidized bed is a defined term in the International Fire Code (IFC) 2009, in Flammable Finishes. The code's own words are: “A container holding powder coating material that is aerated from below so as to form an air-supported expanded cloud of such material that is electrically charged with a charge opposite to that of the object to be coated. Such object is transported through the container immediately above the charged and aerated materials in order to …” No other I-Code in this corpus defines it, so the IFC 2009 definition is the one to work from. The term is used in 2 chapters of this corpus, most often in Flammable Finishes (IFC 2009), Definitions (IFC 2009). These pages transcribe the 2009 model text; verify the definition against the edition and amendments your authority having jurisdiction has adopted.

Content and cited inputs reviewed by Scott Barrington, Harth founder and architectural technology specialist · Published 2026-09-07 · Updated 2026-09-07.

What does this term mean?

Electrostatic Fluidized Bed — IFC 2009, Flammable Finishes:

A container holding powder coating material that is aerated from below so as to form an air-supported expanded cloud of such material that is electrically charged with a charge opposite to that of the object to be coated. Such object is transported through the container immediately above the charged and aerated materials in order to be coated.

Labeled code-term definition diagram: Electrostatic Fluidized Bed: Building Code Definition
How the IFC 2009 define electrostatic fluidized bed, where the wording differs, and which chapters depend on the term.

What must be verified before using this guidance?

Electrostatic Fluidized Bed is defined once in this corpus, in the Flammable Finishes chapter of the International Fire Code (IFC) 2009:

A container holding powder coating material that is aerated from below so as to form an air-supported expanded cloud of such material that is electrically charged with a charge opposite to that of the object to be coated. Such object is transported through the container immediately above the charged and aerated materials in order to be coated.

Where electrostatic fluidized bed is used in the code

The term appears in 2 chapters of the 2009 I-Codes hosted here. The chapters that lean on it hardest are the ones to read next.

ChapterCodeMentions
Flammable FinishesIFC 20093
DefinitionsIFC 20091

The term in use

How the code actually writes about electrostatic fluidized bed, quoted from the 2009 text hosted here:

Operations using finely ground particles of protective finishing material applied in dry powder form by a fluidized bed, an electrostatic fluidized bed, powder spray guns or electrostatic powder spray guns shall comply with this section.

IFC 2009 §1506.1

The terms electrostatic fluidized bed is built out of

The definition above leans on 1 other defined term. Each carries its own code definition, and a local amendment to any of them changes what electrostatic fluidized bed covers:

  • Container — IFC 2009: A vessel of 60 gallons (227 L) or less in capacity used for transporting or storing hazardous materials.

Electrostatic Fluidized Bed: what to open, and in what order

Every row is a document this term depends on. The ICC code library and the ICC adoption maps cover the middle rows.

CheckWhereConfirmed
Read the definition in the adopted IFCFlammable Finishes
Re-check the requirement that uses itFlammable Finishes (IFC 2009)
Re-check the requirement that uses itDefinitions (IFC 2009)
Confirm the dependent definitionContainer
Local amendment to any of the aboveJurisdiction's amendment list

A research aid, not a code determination. The authority having jurisdiction decides which edition and which amendments apply.

Sources and method

Definitions quoted from the 2009 International Codes as transcribed in this site's building-codes collection, with the source chapter linked for each quotation. Usage counts are computed over the chapters hosted here, one copy per code. The ICC code library publishes the current model text and the ICC adoption maps show which edition a jurisdiction has adopted; those sources control.

Frequently asked questions

What is the code definition of electrostatic fluidized bed?

The International Fire Code (IFC) 2009 defines it in Flammable Finishes as: “A container holding powder coating material that is aerated from below so as to form an air-supported expanded cloud of such material that is electrically charged with a charge opposite to that of the object to be coated. Such object is transported through the container immediately above the charged and aerated materials in order to be coated.” The 2009 model text is reproduced here; the definition that binds your project is the one in the edition your jurisdiction has adopted, as amended locally.

Which parts of the code depend on electrostatic fluidized bed?

In this corpus the term is used across 2 chapters, led by Flammable Finishes in the IFC 2009. Those are the sections whose scope moves if the definition is amended locally, so read them together with Chapter 2 rather than on their own.