Last updated September 7, 2026 · Definitions quoted from the 2009 International Codes as transcribed in this site's building-codes collection, with the source chapter linked for each quotation. Usage counts are computed over the chapters hosted here, one copy per code. The [ICC code library](https://codes.iccsafe.org/codes) publishes the current model text and the [ICC adoption maps](https://www.iccsafe.org/advocacy/code-adoption-maps/) show which edition a jurisdiction has adopted; those sources control.
Direct answer
Grandstand is a defined term in the International Building Code (IBC) 2009, in Means of Egress. The code's own words are: “Tiered seating supported on a dedicated structural system and two or more rows high and is not a building element (see "Bleachers").” The IFC 2009 carries the same definition word for word, so the term means the same thing in each. The term is used in 9 chapters of this corpus, most often in Accessibility (IBC 2009), General Requirements (IFC 2009), Means of Egress (IBC 2009). These pages transcribe the 2009 model text; verify the definition against the edition and amendments your authority having jurisdiction has adopted. Record the jurisdiction, the adopted edition, the application date and any local amendment that rewrites the definition before you use it on a live project, because a term redefined by amendment changes every requirement that depends on it.
Content and cited inputs reviewed by Scott Barrington, Harth founder and architectural technology specialist · Published 2026-09-07 · Updated 2026-09-07.
What does this term mean?
Grandstand — IBC 2009, Means of Egress:
Tiered seating supported on a dedicated structural system and two or more rows high and is not a building element (see "Bleachers").

What must be verified before using this guidance?
Two of the I-Codes in this corpus define Grandstand, in identical words.
| Code | Where it is defined | Definition |
|---|---|---|
| IBC 2009 | Means of Egress | Tiered seating supported on a dedicated structural system and two or more rows high and is not a building element (see "Bleachers"). |
| IFC 2009 | Means of Egress | Tiered seating supported on a dedicated structural system and two or more rows high and is not a building element (see" Bleachers"). |
Where grandstand is used in the code
The term appears in 9 chapters of the 2009 I-Codes hosted here. The chapters that lean on it hardest are the ones to read next.
| Chapter | Code | Mentions |
|---|---|---|
| Accessibility | IBC 2009 | 8 |
| General Requirements | IFC 2009 | 6 |
| Means of Egress | IBC 2009 | 5 |
| Definitions | IFC 2009 | 5 |
| Means of Egress | IFC 2009 | 5 |
| Existing Structures | IBC 2009 | 2 |
| Special Detailed Requirements Based on Use and Occupancy | IBC 2009 | 2 |
| Use and Occupancy Classification | IBC 2009 | 2 |
| Definitions | IBC 2009 | 1 |
The term in use
How the code actually writes about grandstand, quoted from the 2009 text hosted here:
Accumulations of wastepaper, wood, hay, straw, weeds, litter or combustible or flammable waste or rubbish of any type shall not be permitted to remain on a roof or in any court, yard, vacant lot, alley, parking lot, open space, or beneath a grandstand, bleacher, pier, wharf, manufactured home, recreational vehicle or other similar structure.
Grandstand compared with Bleachers
These two are the closest pair in the 2009 I-Codes: about 90 per cent of their defining words are the same. The code states both and compares neither, so the difference is worth naming.
| Wording unique to it | |
|---|---|
| Grandstand (IBC 2009) | bleachers |
| Bleachers (IBC 2009) | grandstands |
Everything else in the two definitions is shared. If a project turns on which of the two applies, those words are the whole of the test — and a local amendment that edits one of them without editing the other moves the boundary between grandstand and bleachers.
The terms grandstand is built out of
The definition above leans on 4 other defined terms. Each carries its own code definition, and a local amendment to any of them changes what grandstand covers:
- Building Element — IBC 2009: A fundamental component of building construction, listed in Table 601, which mayor may not be of fire-resistance-rated construction and is constructed of materials based on the building type of construction.
- Bleachers — IBC 2009: Tiered seating supported on a dedicated structural system and two or more rows high and is not a building element (see" Grandstands").
- Building — IBC 2009: Any structure used or intended for supporting or sheltering any use or occupancy.
- System — IFC 2009: An assembly of equipment consisting of a tank, container or containers, appurtenances, pumps, compressors and connecting piping.
Grandstand: what to open, and in what order
Every row is a document this term depends on. The ICC code library and the ICC adoption maps cover the middle rows.
| Check | Where | Confirmed |
|---|---|---|
| Read the definition in the adopted IBC | Means of Egress | |
| Read the definition in the adopted IFC | Means of Egress | |
| Re-check the requirement that uses it | Accessibility (IBC 2009) | |
| Re-check the requirement that uses it | General Requirements (IFC 2009) | |
| Re-check the requirement that uses it | Means of Egress (IBC 2009) | |
| Re-check the requirement that uses it | Definitions (IFC 2009) | |
| Confirm the dependent definition | Building Element | |
| Confirm the dependent definition | Bleachers | |
| Confirm the dependent definition | Building | |
| Local amendment to any of the above | Jurisdiction's amendment list |
A research aid, not a code determination. The authority having jurisdiction decides which edition and which amendments apply.
Where can you explore related guidance?
- Explore all glossary guidance
- Building Element: Building Code Definition
- Bleachers: Building Code Definition
- Building: Building Code Definition
- System: Building Code Definition
Sources and method
Definitions quoted from the 2009 International Codes as transcribed in this site's building-codes collection, with the source chapter linked for each quotation. Usage counts are computed over the chapters hosted here, one copy per code. The ICC code library publishes the current model text and the ICC adoption maps show which edition a jurisdiction has adopted; those sources control.
Source links
Frequently asked questions
What is the code definition of grandstand?
The International Building Code (IBC) 2009 defines it in Means of Egress as: “Tiered seating supported on a dedicated structural system and two or more rows high and is not a building element (see "Bleachers").” The 2009 model text is reproduced here; the definition that binds your project is the one in the edition your jurisdiction has adopted, as amended locally.
Which parts of the code depend on grandstand?
In this corpus the term is used across 9 chapters, led by Accessibility in the IBC 2009. Those are the sections whose scope moves if the definition is amended locally, so read them together with Chapter 2 rather than on their own.
What is the definition of "grandstand"?
In the 2009 I-Codes hosted here it is a defined term rather than a description. The IBC 2009 states, in Means of Egress: “Tiered seating supported on a dedicated structural system and two or more rows high and is not a building element (see "Bleachers").” It is defined in IBC 2009, IFC 2009. Because it is a defined term, whatever the adopted edition says it means is what every section using it means — so check Chapter 2 of that edition and any local amendment before relying on this wording.
What is the definition of a building code?
Building is a separate defined term. The IBC 2009 defines it as: “Any structure used or intended for supporting or sheltering any use or occupancy.” That is not the same as grandstand, which the IBC 2009 defines as “Tiered seating supported on a dedicated structural system and two or more rows high and is not a building element (see "Bleachers").” — read both before applying either, and confirm the wording in the edition your jurisdiction has adopted.
Related pages
- Grade Floor Opening: Building Code Definition
Grade Floor Opening — IBC 2009 definition: A window or other opening located such that the sill height of the opening is not …
- Grade Plane: Building Code Definition
Grade Plane — IBC 2009 definition: A reference plane representing the average of finished ground level adjoining the building at exterior walls.
- Grade: Building Code Definition
Grade — IRC 2009 definition: The finished ground level adjoining the building at all exterior walls.
- Gridded Water Distribution System: Building Code Definition
Gridded Water Distribution System — IRC 2009 definition: A water distribution system where every water distribution pipe is interconnected so as to provide two …
- Gridiron: Building Code Definition
Gridiron — IBC 2009 definition: The structural framing over a stage supporting equipment for hanging or flying scenery and other stage …
- Gross Leasable Area: Building Code Definition
Gross Leasable Area — IBC 2009 definition: The total floor area designed for tenant occupancy and exclusive use.