Building Code Glossary
Site-fabricated Stretch System: Building Code Definition
How the IBC 2009, IFC 2009 define site-fabricated stretch system, where the wording differs, and which chapters depend on the term.
On this page
Last updated September 7, 2026 · Definitions quoted from the 2009 International Codes as transcribed in this site's building-codes collection, with the source chapter linked for each quotation. Usage counts are computed over the chapters hosted here, one copy per code. The [ICC code library](https://codes.iccsafe.org/codes) publishes the current model text and the [ICC adoption maps](https://www.iccsafe.org/advocacy/code-adoption-maps/) show which edition a jurisdiction has adopted; those sources control.
Direct answer
Site-fabricated stretch system is a defined term in the International Building Code (IBC) 2009, in Interior Finishes. The code's own words are: “A system, fabricated on site and intended for acoustical, tackable or aesthetic purposes, that is comprised of three elements: (a) a frame (constructed of plastic, wood, metal or other material) used to hold fabric in place, (b) a core material (infill, with the correct properties for the application), and (c) an outside layer, comprised of …” The IFC 2009 defines the same term with different wording, so the controlling text depends on which code governs the question in front of you — the comparison below sets the versions side by side. The term is used in 4 chapters of this corpus, most often in Interior Finishes (IBC 2009), Interior Finish, Decorative Materials and Furnishings (IFC 2009), Definitions (IBC 2009). These pages transcribe the 2009 model text; verify the definition against the edition and amendments your authority having jurisdiction has adopted.
Content and cited inputs reviewed by Scott Barrington, Harth founder and architectural technology specialist · Published 2026-09-07 · Updated 2026-09-07.
What does this term mean?
Site-fabricated Stretch System — IBC 2009, Interior Finishes:
A system, fabricated on site and intended for acoustical, tackable or aesthetic purposes, that is comprised of three elements: (a) a frame (constructed of plastic, wood, metal or other material) used to hold fabric in place, (b) a core material (infill, with the correct properties for the application), and (c) an outside layer, comprised of a textile, fabric or vinyl, that is stretched taunt and held in place by tension or mechanical fasteners via the frame.

What must be verified before using this guidance?
Two of the I-Codes in this corpus define Site-fabricated Stretch System, and the wording is not identical — read the version that governs your question.
| Code | Where it is defined | Definition |
|---|---|---|
| IBC 2009 | Interior Finishes | A system, fabricated on site and intended for acoustical, tackable or aesthetic purposes, that is comprised of three elements: (a) a frame (constructed of plastic, wood, metal or other material) used to hold fabric in place, (b) a core material (infill, with the correct properties for the application), and (c) an outside layer, comprised of a textile, fabric or vinyl, that is stretched taunt and held in place by tension or mechanical fasteners via the frame. |
| IFC 2009 | Interior Finish, Decorative Materials and Furnishings | A system, fabricated on site and intended for acoustical, tackable or aesthetic purposes, that is comprised of three elements: |
Where site-fabricated stretch system is used in the code
The term appears in 4 chapters of the 2009 I-Codes hosted here. The chapters that lean on it hardest are the ones to read next.
| Chapter | Code | Mentions |
|---|---|---|
| Interior Finishes | IBC 2009 | 3 |
| Interior Finish, Decorative Materials and Furnishings | IFC 2009 | 3 |
| Definitions | IBC 2009 | 1 |
| Definitions | IFC 2009 | 1 |
The terms site-fabricated stretch system is built out of
The definition above leans on 1 other defined term. Each carries its own code definition, and a local amendment to any of them changes what site-fabricated stretch system covers:
- System — IFC 2009: An assembly of equipment consisting of a tank, container or containers, appurtenances, pumps, compressors and connecting piping.
Site-fabricated Stretch System: what to open, and in what order
Every row is a document this term depends on. The ICC code library and the ICC adoption maps cover the middle rows.
| Check | Where | Confirmed |
|---|---|---|
| Read the definition in the adopted IBC | Interior Finishes | |
| Read the definition in the adopted IFC | Interior Finish, Decorative Materials and Furnishings | |
| Re-check the requirement that uses it | Interior Finishes (IBC 2009) | |
| Re-check the requirement that uses it | Interior Finish, Decorative Materials and Furnishings (IFC 2009) | |
| Re-check the requirement that uses it | Definitions (IBC 2009) | |
| Re-check the requirement that uses it | Definitions (IFC 2009) | |
| Confirm the dependent definition | System | |
| Local amendment to any of the above | Jurisdiction's amendment list |
A research aid, not a code determination. The authority having jurisdiction decides which edition and which amendments apply.
Where can you explore related guidance?
- Explore all glossary guidance
- System: Building Code Definition
- Flame Spread Index: Building Code Definition
- Trim: Building Code Definition
- Smoke-developed Index: Building Code Definition
Sources and method
Definitions quoted from the 2009 International Codes as transcribed in this site's building-codes collection, with the source chapter linked for each quotation. Usage counts are computed over the chapters hosted here, one copy per code. The ICC code library publishes the current model text and the ICC adoption maps show which edition a jurisdiction has adopted; those sources control.
Source links
Frequently asked questions
What is the code definition of site-fabricated stretch system?
The International Building Code (IBC) 2009 defines it in Interior Finishes as: “A system, fabricated on site and intended for acoustical, tackable or aesthetic purposes, that is comprised of three elements: (a) a frame (constructed of plastic, wood, metal or other material) used to hold fabric in place, (b) a core material (infill, with the correct properties for the application), and (c) an outside layer, comprised of a textile, fabric or vinyl, that is stretched taunt and held in place by tension or mechanical fasteners via the frame.” The 2009 model text is reproduced here; the definition that binds your project is the one in the edition your jurisdiction has adopted, as amended locally.
Which parts of the code depend on site-fabricated stretch system?
In this corpus the term is used across 4 chapters, led by Interior Finishes in the IBC 2009. Those are the sections whose scope moves if the definition is amended locally, so read them together with Chapter 2 rather than on their own.
Related pages
- Single-ply Membrane: Building Code Definition
Single-ply Membrane — IBC 2009 definition: A roofing membrane that is field applied using one layer of membrane material (either homogeneous or …
- Single-station Smoke Alarm: Building Code Definition
Single-station Smoke Alarm — IBC 2009 definition: An assembly incorporating the detector, the control equipment and the alarm-sounding device in one unit, operated …
- Site Class: Building Code Definition
Site Class — IBC 2009 definition: A classification assigned to a site based on the types of soils present and their engineering …
- Site: Building Code Definition
Site — IBC 2009 definition: A parcel of land bounded by a lot line or a designated portion of a public …
- Skylight, Unit: Building Code Definition
Skylight, Unit — IBC 2009 definition: A factory-assembled, glazed fenestration unit, containing one panel of glazing material that allows for natural lighting …
- Skylight: Building Code Definition
Skylight — IECC 2009 definition: Glass or other transparent or translucent glazing material installed at a slope of 15 degrees (0.26 …
The AI-powered workspace for architects.