Updated 2026-08-14

Structural Design Loads

Design Wind Speed (Vult), Risk Category Maps & Exposure B/C/D

Plain-language guide to ultimate design wind speed (Vult), exposure categories B/C/D, and how risk category selects the right wind map for a project.

On this page

Last updated August 14, 2026 · Concepts per ASCE 7 (Ch. 26–30); mapped basic wind speeds by risk category from the ASCE Hazard Tool. Any values shown are illustrative and the official ASCE Hazard Tool + AHJ-adopted code govern. Official references: [ASCE Hazard Tool](https://ascehazardtool.org/); [ASCE/SEI 7-22](https://www.asce.org/publications-and-news/codes-and-standards/asce-sei-7-22); [2024 IBC Chapter 16](https://codes.iccsafe.org/content/IBC2024P1/chapter-16-structural-design); [2021 IBC Chapter 16](https://codes.iccsafe.org/content/IBC2021P2/chapter-16-structural-design); [FEMA fact sheet: ASCE 7-22 wind load changes](https://www.fema.gov/sites/default/files/documents/fema_asce-7-22-wind-highlights_fact-sheet_2022.pdf).

Direct answer

Plain-language guide to ultimate design wind speed (Vult), exposure categories B/C/D, and how risk category selects the right wind map for a project. A key reference is typical inland range: 95–115 mph; check the cited source, edition, units, and applicability before using it for design, compliance, procurement, or approval. Symbol is Vult (mph); ultimate/basic design wind speed. Typical inland range is 95–115 mph; Risk Cat. II, illustrative. Coastal / hurricane is 130–180+ mph; special wind regions. The ultimate (basic) design wind speed, Vult, in mph, is a 3-second gust at 33 ft above open (Exposure C) terrain. Since ASCE 7-10 the maps are strength-level, so Vult feeds directly into strength design without an extra wind load factor. ASCE 7 provides a separate map per risk category, so importance changes the speed you read.

Content and cited inputs reviewed by Harth team · Published 2026-08-14 · Updated 2026-08-14.

What does this term mean?

Ultimate Design Wind Speed & Exposure Categories Explained: Plain-language guide to ultimate design wind speed (Vult), exposure categories B/C/D, and how risk category selects the right wind map for a project.

Labeled structural load diagram: Ultimate Design Wind Speed & Exposure Categories Explained
Plain-language guide to ultimate design wind speed (Vult), exposure categories B/C/D, and how risk category selects the right wind map for a project.

Which site and code inputs control the design?

The ultimate (basic) design wind speed, Vult, in mph, is a 3-second gust at 33 ft above open (Exposure C) terrain. Since ASCE 7-10 the maps are strength-level, so Vult feeds directly into strength design without an extra wind load factor. ASCE 7 provides a separate map per risk category, so importance changes the speed you read.

Risk CategoryBuilding typeReturn period
ILow hazard (minor storage)~300 yr
IIStandard (most buildings)~700 yr
IIISubstantial hazard (assembly)~1,700 yr
IVEssential (hospitals, EOCs)~3,000 yr

Which risk category wind map applies

There is no separate "wind risk category map". Set the risk category from the building's use and occupant load under IBC Table 1604.5, then read the speed from the map drawn for that category:

Risk CategoryTypical triggers (2024 IBC Table 1604.5, abridged)2024 IBC wind map
ILow hazard to life: agricultural facilities, certain temporary facilities, minor storageFigure 1609.3(1)
IIEverything not listed in I, III or IVFigure 1609.3(2)
IIIPrimary occupancy public assembly over 300; Group E or I-4 over 250; education above 12th grade over 500; any occupancy over 5,000Figure 1609.3(3)
IVEssential facilities: Group I-2 Condition 2, fire, rescue, ambulance and police stations, designated emergency shelters, emergency operations centersFigure 1609.3(4)

The 2021 IBC spreads the same four categories over Figures 1609.3(1)–(12). The 2021 and 2024 IBC both call the mapped value the basic design wind speed, V; the 2015 IBC called it the ultimate design wind speed, Vult. Either way it is a 3-second gust at 33 ft in Exposure C, and the 2024 IBC points to the ASCE Wind Design Geodatabase for location-specific values.

ASCE 7-22, the standard behind the 2024 IBC, revised the maps mainly in hurricane-prone regions. FEMA's summary lists decreases along the North Atlantic coast (the 130 mph Risk Category II contour moved offshore), increases on the south Texas coast (about 10 mph) and in parts of the western Florida panhandle, and slight decreases on the Alabama, Mississippi and Louisiana coasts. Examples for Risk Category II: Mobile, AL went from 154 to 146 mph and Destin, FL from 142 to 152 mph. The Risk Category I, III and IV maps moved in the same way.

Exposure categories

Exposure describes the upwind ground roughness and can vary by wind direction:

  • Exposure B — urban, suburban, wooded; the most sheltered, lowest pressures.
  • Exposure C — open terrain with scattered obstructions; the common default.
  • Exposure D — flat, unobstructed terrain, shorelines, and open water; highest pressures.

Moving from B toward D raises wind pressure meaningfully at low heights, so the exposure call is not a formality.

Exposure B, C and D: the upwind distance rules

For each wind direction, check the two 45° sectors either side of it and use whichever exposure gives the higher load (2024 IBC Section 1609.4.1, following ASCE 7 Section 26.7). Classify the upwind surface roughness, then test the fetch:

ExposureUpwind groundRequired fetch (2024 IBC Section 1609.4.3)
BSurface Roughness B: urban, suburban or wooded, with numerous closely spaced obstructions the size of single-family dwellings or larger1,500 ft for mean roof height ≤ 30 ft; the greater of 2,600 ft or 20× building height above 30 ft
CAny site that does not qualify as B or D; Surface Roughness C is open terrain with scattered obstructions generally under 30 ft, flat open country and grasslandNone
DSurface Roughness D: flat, unobstructed areas and water surfaces, including mud flats, salt flats and unbroken iceThe greater of 5,000 ft or 20× building height

Exposure D also reaches inland. A site with B or C roughness immediately upwind is still Exposure D if it lies within the greater of 600 ft or 20× building height of a D condition. Buildings taller than 130 ft therefore need more than 2,600 ft of suburban fabric upwind to qualify for B. ASCE 7-22 also revised the velocity pressure coefficient Kz (Section 26.10), the factor through which exposure changes pressure, so confirm pressures against the edition your jurisdiction has adopted.

Illustrative wind speeds

SettingIllustrative Vult (Risk Cat. II)
Interior low-wind region95–105 mph
Transitional / plains105–120 mph
Hurricane-prone coast130–180+ mph

Get the authoritative value

Read the exact Vult for each risk category from the ASCE Hazard Tool at your project address, then set exposure from the actual surrounding terrain. To sanity-check terrain and exposure against real surroundings, drop the address into Harth and study the site context before your engineer finalizes the wind design.

Design Wind Speed (Vult), Risk Category Maps & Exposure B/C/D: structural-engineer handoff record

Required inputProject entry
Site coordinates and jurisdiction—
Adopted code / standard and edition—
Risk category and occupancy basis—
Official hazard-tool result and retrieval date—
Site class, exposure, terrain or other relevant site input—
Local amendments and authority confirmation—
Engineer's derived design values—
Engineer, checker and revision—

Stop condition: this page explains terminology and source workflow only. A generated diagram, map colour or generic example must not become a project design value.

Sources and method

Concepts per ASCE 7 (Ch. 26–30); mapped basic wind speeds by risk category from the ASCE Hazard Tool. Any values shown are illustrative and the official ASCE Hazard Tool + AHJ-adopted code govern. Official references: ASCE Hazard Tool; ASCE/SEI 7-22; 2024 IBC Chapter 16; 2021 IBC Chapter 16; FEMA fact sheet: ASCE 7-22 wind load changes.

Frequently asked questions

What does 'ultimate' design wind speed mean?

Since ASCE 7-10, wind maps give the ultimate (strength-level) basic wind speed Vult — a 3-second gust at 33 ft in Exposure C, tied to a return period that varies by risk category. It is used directly in strength design load combinations, so it is not multiplied by a load factor the way older allowable-stress (Vasd) speeds were. Confirm which speed a legacy calculation uses before comparing numbers.

How do I pick an exposure category?

Exposure describes the ground roughness upwind of the building. Exposure B is suburban, wooded, or built-up terrain; Exposure C is open terrain with scattered obstructions (most sites default here if unsure); Exposure D is flat, unobstructed terrain including shorelines and open water. Exposure can differ by wind direction, and moving from B to D substantially increases wind pressures — so the choice materially affects the design.

Why does the wind speed change with risk category?

ASCE 7 publishes separate wind maps for each risk category so that more important buildings are designed for a rarer, stronger event. A Risk Category IV essential facility uses a higher Vult than a Risk Category II building at the same location, reflecting a longer return period and lower acceptable probability of failure.

Is there a wind risk category map?

Not as a separate map. Risk category comes from the building's use and occupant load under IBC Table 1604.5; for example, buildings whose main occupancy is public assembly over 300 people are Risk Category III, and fire stations are IV. ASCE 7 and the IBC then publish one basic wind speed map per risk category (2024 IBC Figures 1609.3(1)–(4)), so a Risk Category IV building reads a higher speed than a Risk Category II building on the same lot.

What is the difference between exposure category B and C?

Exposure B needs Surface Roughness B (urban, suburban or wooded ground with closely spaced obstructions the size of houses or larger) to extend upwind at least 1,500 ft for buildings up to 30 ft tall, or the greater of 2,600 ft or 20 times the height for taller ones (2024 IBC Section 1609.4.3). Where that fetch is missing in a wind sector, the site is Exposure C, which produces higher wind pressures at the same wind speed.

Does the design wind speed change with exposure category?

No. The mapped basic wind speed is always defined as a 3-second gust at 33 ft above ground in Exposure C, whatever the real site exposure. Exposure enters afterwards through the velocity pressure exposure coefficient Kz, which lowers pressure for Exposure B and raises it for Exposure D. An 'Exposure C wind speed' is simply the value read from the map; the site's own exposure changes the pressure, not the speed.

When does Exposure D apply near water?

Exposure D applies where flat, unobstructed ground or open water extends upwind for at least 5,000 ft or 20 times the building height, whichever is greater. It also carries inland: a site with B or C roughness immediately upwind is still Exposure D if it sits within 600 ft or 20 times the building height, whichever is greater, of that D condition. Check each wind direction separately, because a lakefront lot may be D from one side only.

The AI-powered workspacefor architects.